X-ray detection with zinc-blende (cubic) GaN Schottky diodesTools Gohil, T., Whale, J., Lioliou, G., Novikov, Sergei V., Foxon, C.T., Kent, A.J. and Barnett, A.M. (2016) X-ray detection with zinc-blende (cubic) GaN Schottky diodes. Scientific Reports, 6 . 29535/1-29535/5. ISSN 2045-2322 Full text not available from this repository.
Official URL: http://www.nature.com/articles/srep29535
AbstractThe room temperature X-ray responses as functions of time of two n type cubic GaN Schottky diodes (200 μm and 400 μm diameters) are reported. The current densities as functions of time for both diodes showed fast turn-on transients and increases in current density when illuminated with X-ray photons of energy up to 35 keV. The diodes were also electrically characterized: capacitance, implied depletion width and dark current measurements as functions of applied bias at room temperature are presented. At −5 V reverse bias, the capacitances of the diodes were measured to be (84.05 ± 0.01) pF and (121.67 ± 0.02) pF, respectively. At −5 V reverse bias, the dark current densities of the diodes were measured to be (347.2 ± 0.4) mA cm−2 and (189.0 ± 0.2) mA cm−2, respectively. The Schottky barrier heights of the devices (0.52 ± 0.07) eV and (0.63 ± 0.09) eV, respectively, were extracted from the forward dark current characteristics.