Corona discharge and arcing around wires under the influence of high electric fieldsTools Evans, John Lee (2018) Corona discharge and arcing around wires under the influence of high electric fields. PhD thesis, University of Nottingham.
AbstractAn Electromagnetic Pulse (EMP) resulting from, for example, the detonation of a nuclear weapon is characterised by a wave of electromagnetic activity able to couple with power lines and electro-sensitive equipment with the potential of rendering an establishment or on a greater scale, a whole city impotent. Protection against such occurrences is of paramount importance. It is now accepted that an important consideration when devising protective schemes against such phenomena is an accurate understanding of the effects on propagating waveforms such as those coupled to wires, when electrical breakdown of the dielectric material surrounding such wires occurs, otherwise known as electrical discharge. Such issues can occur around the affected wires if the electric fields generated exceed the dielectric strength of the surrounding medium, typically air or soil. Under these circumstances, the signature of the coupled waveform is known to change in characteristic ways. The form and degree of distortion needs to be understood if the harmful effects are to be prevented by protection systems put in place.