A series hybrid “real inertia” energy storage system

Rouse, James Paul, Garvey, Seamus D., Cardenas, B. and Davenne, T.R. (2018) A series hybrid “real inertia” energy storage system. Journal of Energy Storage, 20 . pp. 1-15. ISSN 2352-152X

[img]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
Available under Licence Creative Commons Attribution Non-commercial No Derivatives.
Download (1MB) | Preview

Abstract

The wide scale market penetration of numerous renewable energy technologies is dependent, at least in part, on developing reliable energy storage methods that can alleviate concerns over potentially interrupted and uncertain supplies. Many challenges need to be overcome, not least among them is allowing capacity for the wide range of time scales required to ensure grid stability. In thermal power plant, high frequency/short duration demand fluctuations, acting at the milliseconds to several seconds time scale, are addressed passively by the inertia of the grid. Here, grid inertia can be thought of as the mechanical inertia of spinning steel in steam and gas turbines. This allows time for active control measures to take effect at the tens of second to hours time scale and for the system to recover without a supply frequency deviation that is noticeable to the customer. It is of paramount importance that, as thermal plant is retired, renewable energy generation and storage systems account for the loss of this inertia. In the literature, strategies to address the loss of “real” inertia have often relied on emulation rather than actual replacement. The present work focuses on the preliminary development of a novel energy storage system that makes use of real inertia to address short term supply/demand imbalances while simultaneously allowing for extended depths of discharge. The concept looks to combine flywheel and compressed fluid energy stores in order to power a synchronous generator. By combining these energy storage technologies through a differential drive unit, DDU, it is anticipated that the benefits of high system inertia can be exploited in the short term while allowing energy to be continually extracted from the flywheel in the long term during storage discharge. The use of a DDU makes the present design particularly novel and distinct from other hybrid systems. In essence, this inclusion allows energy to be extracted entirely from the flywheel, inducing “real” inertia, or entirely from the secondary store, inducing “synthetic” inertia, or some combination of the two. Fundamental sizing calculations for a 50MW system with 20MWh of storage capacity are presented and used to design a suitable control system that allows for the operation of both primary flywheel and secondary compressed fluid energy stores. The transient behaviour of the system is simulated for several charge/discharge time profiles to demonstrate response stability for the system. Comments on system turnaround efficiency, which is dependent upon loading history but for the intended applications can be considered to be greater than 90% are also made here, along with a case study application to an isolated Californian solar powered grid.

Item Type: Article
Keywords: Real inertia; Hybrid energy storage; Kinetic energy storage; Frequency response
Schools/Departments: University of Nottingham, UK > Faculty of Engineering > Department of Mechanical, Materials and Manufacturing Engineering
Identification Number: https://doi.org/10.1016/j.est.2018.08.006
Depositing User: Rouse, James
Date Deposited: 10 Sep 2018 07:40
Last Modified: 04 Sep 2019 04:30
URI: https://eprints.nottingham.ac.uk/id/eprint/53840

Actions (Archive Staff Only)

Edit View Edit View