Modelling and parametric study of the re-anchorage of ruptured tendons in bonded post-tensioned concrete

Abdelatif, Amged O., Owen, John S. and Hussein, Mohammed F.M. (2017) Modelling and parametric study of the re-anchorage of ruptured tendons in bonded post-tensioned concrete. Journal of Structural Engineering, 143 (12). 04017162/1-04017162/16. ISSN 1943-541X

Full text not available from this repository.

Abstract

The contribution of ruptured tendons to the residual strength of bonded post-tensioned concrete structures is currently assessed based on pre-tensioned concrete bond models. However, this approach is inaccurate due to the inherent differences between pre-tensioned and post-tensioned concrete. In this paper, a non-linear 3D finite element model is developed for the re-anchoring of a ruptured tendon in post-tensioned concrete. The model is validated using full-field displacement measurement from 33 post-tensioned concrete prisms and previous experimental data on beams from the literature. The influence of different parameters was investigated, including tendon properties (i.e. diameter, roughness), duct properties (i.e. diameter, thickness, material), initial prestress, concrete strength, grout strength, grout voids, stirrups, and strands, on the tendon re-anchorage. The most influential parameters are found to be tendon and duct properties.

Item Type: Article
RIS ID: https://nottingham-repository.worktribe.com/output/964005
Additional Information: © 2017 American Society of Civil Engineers
Keywords: Post-tensioned concrete; Re-anchorage; Corrosion; Tendon; Bond, Modelling; Finite element; Rupture; ESPI
Schools/Departments: University of Nottingham, UK > Faculty of Engineering > Department of Civil Engineering
Identification Number: https://doi.org/10.1061/(ASCE)ST.1943-541X.0001898