Hearing instruments for unilateral severe-to-profound sensorineural hearing loss in adults

Kitterick, Pádraig T., Smith, Sandra Nelson and Lucas, Laura (2016) Hearing instruments for unilateral severe-to-profound sensorineural hearing loss in adults. Ear and Hearing, 37 (5). pp. 495-507. ISSN 1538-4667

Full text not available from this repository.

Abstract

Objectives: A systematic review of the literature and meta-analysis was conducted to assess the nature and quality of the evidence for the use of hearing instruments in adults with a unilateral severe-to-profound sensorineural hearing loss.

Design: The PubMed, EMBASE, MEDLINE, Cochrane, CINAHL and DARE databases were searched with no restrictions on language. The search included articles from the start of each database until 11th February 2015. Studies were included that: (a) assessed the impact of any form of hearing instrument, including devices that re-route signals between the ears or restore aspects of hearing to a deaf ear, in adults with a sensorineural severe-to-profound loss in one ear and normal or near-normal hearing in the other ear; (b) compared different devices or compared a device to placebo or the unaided condition; (c) measured outcomes in terms of speech perception, spatial listening, or quality of life; (d) were prospective controlled or observational studies. Studies that met prospectively-defined criteria were subjected to random-effects meta-analyses.

Results: Twenty-seven studies reported in thirty articles were included. The evidence was graded as low-to-moderate quality having been obtained primarily from observational before-after comparisons. The meta-analysis identified statistically-significant benefits to speech perception in noise for devices that re-routed the speech signals of interest from the worse ear to the better ear using either air or bone conduction (mean benefit 2.5 dB). However, these devices also degraded speech understanding significantly and to a similar extent (mean deficit 3.1 dB) when noise was re-routed to the better ear. Data on the effects of cochlear implantation on speech perception could not be pooled as the prospectively-defined criteria for meta-analysis were not met. Inconsistency in the assessment of outcomes relating to sound localisation also precluded the synthesis of evidence across studies. Evidence for the relative efficacy of different devices was sparse but a statistically significant advantage was observed for re-routing speech signals using abutment-mounted bone conduction devices when compared to outcomes after pre-operative trials of air-conduction devices when speech and noise were co-located (mean benefit 1.5 dB). Patients reported significant improvements in hearing-related quality of life with both re-routing devices and following cochlear implantation. Only two studies measured health-related quality of life and findings were inconclusive.

Conclusions: Devices that re-route sounds from an ear with a severe-to-profound hearing loss to an ear with minimal hearing loss may improve speech perception in noise when signals of interest are located towards the impaired ear. However, the same device may also degrade speech perception as all signals are re-routed indiscriminately, including noise. While the restoration of functional hearing in both ears through cochlear implantation could be expected to provide benefits to speech perception, the inability to synthesise evidence across existing studies means that such a conclusion cannot yet be made. For the same reason, it remains unclear whether cochlear implantation can improve the ability to localise sounds despite restoring bilateral input. Prospective controlled studies that measure outcomes consistently and control for selection and observation biases are required to improve the quality of the evidence for the provision of hearing instruments to patients with unilateral deafness and to support any future recommendations for the clinical management of these patients.

Item Type: Article
RIS ID: https://nottingham-repository.worktribe.com/output/975163
Keywords: Air conduction; Bone conduction; Cochlear implantation; Contralateral routing of signals; Localization; Meta-analysis; Quality of life; Re-routing devices; Restorative devices; Single-sided deafness; Speech perception; Systematic review; Unilateral deafness; Unilateral hearing loss
Schools/Departments: University of Nottingham, UK > Faculty of Medicine and Health Sciences > School of Medicine > Division of Clinical Neuroscience
University of Nottingham, UK > Faculty of Medicine and Health Sciences > School of Medicine
Identification Number: https://doi.org/10.1097/AUD.0000000000000313
Depositing User: Kitterick, Dr Padraig
Date Deposited: 24 Jan 2017 15:00
Last Modified: 04 May 2020 20:01
URI: https://eprints.nottingham.ac.uk/id/eprint/39250

Actions (Archive Staff Only)

Edit View Edit View